Intermediate relay MRP-4-1 in the case 22mm DIN-rail
MRP-4-1 ACDC230V UHL4
|
1118.00 руб. с НДС
|
-
Are applied to amplification, galvanic decoupling and increasing the amount of contacts of used equipment
-
Indication of output status
-
4 groups of contacts on output
-
Built-in protection of switching element against inductive emissions arising from the opening of the relay
-
Width of the case is 22mm
PURPOSE OF THE RELAY
Intermediate relays (auxiliary) type of MRP-4-1 are designed for galvanic isolation between power circuits and circuits of control of remote activation load by applying a control voltage to the input of the relay, as well as for use as an intermediate relay.
DESIGN OF THE RELAY
Relay is produced in a plastic case with a unified front connection wires power and switched circuits. Mounting is carried out on a DIN rail width 35mm (GOST R IEC 60715-2003) or on a smooth surface. To set on a smooth surface, you need to push locks. Terminal design provides robust clamp wires up to 2,5mm2. On the front panel there is yellow indicator os status contact group and circuit connection.
OPERATION OF THE RELAY
Switching the relay is carried out by a supplying control voltage to the power contacts, with switch-on indicator lights on the front panel.
A parameter
|
Unit
|
MRP-4-1 ACDC12V
|
MRP-4-1 ACDC24V
|
MRP-4-1 ACDC48V
|
MRP-4-1 ACDC110V
|
MRP-4-1 ACDC230V
|
Supply voltage
|
V
|
ACDC12
|
ACDC24
|
ACDC48
|
ACDC110
|
ACDC230
|
Power consumption of the coil, not more
|
W
|
1,2
|
0,8
|
0,8
|
1,1
|
1,2
|
Time in switched on state
|
|
not limited
|
||||
Time relay switching on, not more
|
ms
|
25
|
||||
Time relay switching off, not more
|
ms
|
50
|
||||
Quantity and type of contacts
|
|
4 switching groups
|
||||
Maximum switching voltage
|
V
|
250
|
||||
Maximum switching current: AC250V 50Hz (AC1)/DC30V (DC1)
|
А
|
8
|
||||
Maximum switching power: АС250V 50Hz (АС1)/DC30V (DC1)
|
ВА/Вт
|
2000/240
|
||||
Electrical strength (supply - contacts)
|
V
|
АС2000 (50Hz - 1min)
|
||||
Mechanical endurance, not less
|
cycles
|
10х106
|
||||
Electrical endurance, not less
|
cycles
|
100000
|
||||
Maximum operating rate, not more
|
cycle/h
|
600
|
||||
Operating temperature range (different versions)
|
0C
|
-25…+55 (UHL4)
-40…+55 (UHL2)
|
||||
Storage temperature
|
0C
|
-40…+70
|
||||
Immunity to interference from bursts in accordance with GOST R 51317.4.4-99 (IEC/EN 61000-4-4)
|
|
level 3 (2kV/5kHz)
|
||||
Immunity to interference over voltage in accordance with GOST R 51317.4.5-99 (IEC/EN 61000-4-5)
|
|
level 3 (2kV A1-A2)
|
||||
Climatic modification and placement category by GOST 15150-69 (non-condensing)
|
|
UHL4 or UHL2
|
||||
The degree's protection at case/terminals according to by GOST 14254-96
|
|
IP40/IP20
|
||||
The degree of pollution in accordance with GOST 9920-89
|
|
2
|
||||
Relative humidity of air
|
%
|
up to 80 (at 250C)
|
||||
Operating position in space
|
|
artbitrary
|
||||
Mode
|
|
round the clock
|
||||
Dimensions
|
mm
|
22х93х62
|
||||
Weight
|
kg
|
0,06
|
CIRCUIT CONNECTION
DIMENSIONS OF THE RELAY
Title
|
Order code
|
File to download
(manual) |
File date
|
MRP-4-1 ACDC12V UHL2
|
4640016938025
|
v01.07.2015
|
|
MRP-4-1 ACDC12V UHL4
|
4640016938032
|
||
MRP-4-1 ACDC24V UHL2
|
4640016938049
|
||
MRP-4-1 ACDC24V UHL4
|
4640016938056
|
||
MRP-4-1 ACDC48V UHL2
|
4640016938063
|
||
MRP-4-1 ACDC48V UHL4
|
4640016938070
|
||
MRP-4-1 ACDC110V UHL2
|
4640016938087
|
||
MRP-4-1 ACDC110V UHL4
|
4640016938094
|
||
MRP-4-1 ACDC230V UHL2
|
4640016938100
|
||
MRP-4-1 ACDC230V UHL4
|
4640016938117
|